<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Rahavard Salamat Journal</title>
<title_fa>مجله ره آورد سلامت</title_fa>
<short_title>RSJ</short_title>
<subject>Medical Sciences</subject>
<web_url>http://rsj.iums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn></journal_id_issn>
<journal_id_issn_online>2588-3089</journal_id_issn_online>
<journal_id_pii>0</journal_id_pii>
<journal_id_doi>0</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>00</journal_id_sid>
<journal_id_nlai>0000</journal_id_nlai>
<journal_id_science>00</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1397</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2019</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>4</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>طراحی سیستم تهویه موضعی جهت کاهش ذرات قابل استنشاق در واحد سنگ سمباده</title_fa>
	<title>Local ventilation system designed to respirable particles reduce in Abrasive vitrified unit</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;strong&gt;زمینه و هدف: &lt;/strong&gt;اهمیت هوای پاک در محیط های صنعتی به خوبی شناخته شده است. صنایع تعداد بی شماری مواد شیمیایی را مورد استفاده قرار می دهند که بسیاری از آنها سمی می باشد. تهویه ی صنعتی مناسب می تواند شرایط ارامش و آسایش کارکنان را به وجود آورد و در نتیجه پرسنل، کار خود را به نحو احسن انجام می دهند و بر روی بازده کاری آن ها تاثیر مثبتی خواهد گذاشت&lt;span dir=&quot;LTR&quot;&gt; .&lt;/span&gt; مطالعه حاضر با هدف تعیین میزان غلظت آلاینده هوا در واحد سنگ سمباده و طراحی سیستم تهویه موضعی مناسب به منظور کاهش غلظت ذرات انجام شد.&amp;nbsp;&lt;br&gt;
&lt;strong&gt;روش کار: &lt;/strong&gt;این مطالعه توصیفی &amp;ndash; تحلیلی بود که در یک صنعت فلزی در سه مرحله انجام شد. مرحله اول: بررسی و تعیین پلان کارگاه و موقعیت منابع تولید آلاینده، مرحله دوم: نمونه برداری و تعیین غلظت آلاینده ها، مرحله سوم: طراحی سیستم تهویه موضعی.&lt;span dir=&quot;LTR&quot;&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;یافته&#8204;ها: &lt;/strong&gt;طبق استاندارد حدود مجازتماس شغلی برای کروم و نیکل در محیط کار به ترتیب برابر با 01/0و 1/0 &lt;span dir=&quot;LTR&quot;&gt;mg/m3&lt;/span&gt; می باشد. غلظت آنالیز نمونه های کروم و نیکل در سالن آبکاری کمتر از حد مجاز بود. در حالی که در سالن ماشین کاری قسمت سمباده 1 و 2 غلظت ذرات قابل استنشاق تقریباً 4 برابر حدود مجاز تماس شغلی به ترتیب 75/11 و 62/13 &lt;span dir=&quot;LTR&quot;&gt;mg/m3&lt;/span&gt; بود. با توجه به نتایج حاصل از آنالیز نمونه های مدنظر، سیستم تهویه موضعی برای واحد سمباده کاری طراحی شد&lt;span dir=&quot;LTR&quot;&gt;.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;نتیجه گیری: &lt;/strong&gt;سیستم تهویه موضعی طراحی شده امکان ربایش و کنترل ذرات در سالن ماشین کاری قسمت سمباده را به طور مؤثری داشت.&lt;span dir=&quot;LTR&quot;&gt;&lt;/span&gt;&lt;br&gt;
&lt;span dir=&quot;LTR&quot;&gt;&lt;/span&gt;</abstract_fa>
	<abstract>&lt;pre&gt;
&lt;strong&gt;Background&lt;/strong&gt;: the importance of clean air is well known in industrial environments. Industries used in numerous Chemicals that many of them are toxic. Proper industrial ventilation can create a sense of calm and comfort for the staff, as a result of which the staff performs well and will have a positive impact on their performance. This study was aimed to determine the concentration of air pollutants in unit abrasive vitrified and local ventilation system design appropriate to reduce the concentration of particles.&lt;/pre&gt;
&lt;strong&gt;Methods&lt;/strong&gt;: This study was cross &amp;ndash; sectional that conducted in one metal industry in three phases. First step: Investigate and determine of planning workshops and of pollutants produced location, second stage: sampling and determining the concentrations of contaminants, the third stage: Design of local ventilation system. &lt;span dir=&quot;RTL&quot;&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;Results&lt;/strong&gt;: According to the standard, the occupational exposure limits for chromium and nickel in the workplace are 0.01 and 0.1 mg / m3, respectively. The concentration of chromium and nickel in the plating room was lower than the permissible concentration. while the concentration of particles in the grinding section 1 and 2 over the permissible level and as 11.75 and 13.62 mg / m&lt;sup&gt;3&lt;/sup&gt;, respectively. The local ventilation system was designed according to speed pressure method for grinding unit.&lt;span dir=&quot;RTL&quot;&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;Conclusion&lt;/strong&gt;: Local ventilation system is designed the possibility of particles capture and control to be effective in the machining salon of grinding section.</abstract>
	<keyword_fa>طراحی, سیستم تهویه, فشار سرعت, آلاینده هوا</keyword_fa>
	<keyword>design, ventilation system, speed pressure, air pollutants</keyword>
	<start_page>13</start_page>
	<end_page>24</end_page>
	<web_url>http://rsj.iums.ac.ir/browse.php?a_code=A-10-160-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohsen</first_name>
	<middle_name></middle_name>
	<last_name>Souy Laky</last_name>
	<suffix></suffix>
	<first_name_fa>محسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سوری لکی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mohsensouri70@gmail.com</email>
	<code>10031947532846001300</code>
	<orcid>10031947532846001300</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>isfahan university of medical science</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name>somaye</first_name>
	<middle_name></middle_name>
	<last_name>barakat</last_name>
	<suffix></suffix>
	<first_name_fa>سمیه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>برکات</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>miss.barakat@yahoo.com</email>
	<code>10031947532846001301</code>
	<orcid>10031947532846001301</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>isfahan university of medical science</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name>kosar</first_name>
	<middle_name></middle_name>
	<last_name>tohidizadeh</last_name>
	<suffix></suffix>
	<first_name_fa>کوثر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>توحیدی زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>kosar.tohidizadeh96@gmail.com</email>
	<code>10031947532846001302</code>
	<orcid>10031947532846001302</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>mashhad university of medical scienceiran university of medical science</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی مشهد</affiliation_fa>
	 </author>


	<author>
	<first_name>Peyman</first_name>
	<middle_name></middle_name>
	<last_name>Yari</last_name>
	<suffix></suffix>
	<first_name_fa>پیمان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>yari.1989@yahoo.com</email>
	<code>10031947532846001303</code>
	<orcid>10031947532846001303</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>iran university of medical science</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
